Application | Domestic hot water heater with tank-in-tank system. The system consists of a stainless steel tank for domestic hot water heating, which is located inside another tank. The external tank acts as a general heat exchanger and is a hollow tank with hot water circulating inside. |
Execution | The outer tank is made of high quality S235JR EN10025 carbon steel, assembled and welded by automatic welding. The internal hot water storage tank is made of high quality AISI 316 Ti stainless steel, assembled and welded by automatic welding. |
Anti-corrosion coating | After welding, the stainless steel inner tank is made: weld passivation and surface etching. |
Cathodic protection | Threaded magnesium anode. |
Insulation and type of outer cover | Non-removable hard polyurethane casing, PVC outer cover with zip and thermal cover. |
Certificates | Complies with directive 97/23 / CE Art. 3 - Part 3. |
Model | 112 | 156 | 201 | 241 | 330 | 550 | 800 | 1000 | ||
Real tank capacity | l | 101 | 165 | 204 | 244 | 270 | 470 | 736 | 860 | |
d | Real tank capacity for the primary circuit | l | 129 | 206 | 254 | 304 | 360 | 595 | 920 | 1090 |
D | Insulated diameter | mm | 550 | 550 | 550 | 550 | 650 | 750 | 1020 | 1020 |
HT | Total height | mm | 975 | 1195 | 1435 | 1710 | 1435 | 1870 | 1930 | 2220 |
Tank heat exchange area | m 2 | 1.35 | 1.73 | 2.10 | 2.50 | 2.70 | 3.60 | 4.70 | 5.30 | |
TO | Maximum tilt height | mm | 1074 | 1291 | 1493 | 1751 | 1642 | 1968 | 2153 | 2410 |
Total weight | Kg | 70 | 85 | 90 | 105 | 130 | 155 | 210 | 230 | |
Connections | ||||||||||
CP | Primary input-output | G1 "¼ | G1 "¼ | G1 "¼ | G1 "¼ | G1 "¼ | G1 "¼ | G2 " | G2 " | |
CS | Secondary circuit input-output | G¾ " | G¾ " | G¾ " | G¾ " | G¾ " | G¾ " | G¾ " | G¾ " | |
Sf | Air hole | G3 / 8 " | G3 / 8 " | G3 / 8 " | G3 / 8 " | G3 / 8 " | G3 / 8 " | G3 / 8 " | G3 / 8 " | |
S | Draining | G3 / 8 " | G3 / 8 " | G3 / 8 " | G3 / 8 " | G3 / 8 " | G3 / 8 " | G3 / 8 " | G3 / 8 " | |
RE | Electric heater hole | G1 "¼ | G1 "¼ | G1 "¼ | G1 "¼ | G1 "¼ | G1 "¼ | G1 "¼ | G1 "¼ | |
So | Sensor hole | G½ " | G½ " | G½ " | G½ " | G½ " | G½ " | G½ " | G½ " | |
T | Thermometer / thermostat hole | G½ " | G½ " | G½ " | G½ " | G½ " | G½ " | G½ " | G½ " | |
Technical details | ||||||||||
PE | Maximum operating pressure for the secondary heating circuit | bar | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 |
PC | Test pressure for the secondary coolant circuit | bar | nine | nine | nine | nine | nine | nine | nine | nine |
TE | Maximum working temperature | ° C | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 |
PS | Maximum working pressure for the wall of the primary circuit tank | bar | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 |
Delivery
- Pickup from a warehouse in Kiev
- New Mail - at the rates of the delivery service
- SAT - at the rates of the delivery service
- Deliveri - at the rates of the delivery service
Payment
- Cashless payment with VAT
- Online Privat24, Visa / MasterCard