loading

Indirect heating boiler 3000 liters OPEKS-2-3000-CSE-HHW-L

Indirect heating boiler 3000 liters OPEKS23000CSEHHWLIndirect heating boiler 3000 liters OPEKS23000CSEHHWL
in stock
Price: specify

Quantity

Total

specify

  • Manufacturer: OPEKS
  • Volume: 3000(l)
  • Container material: enamel coated carbon steel
  • Maximum operating pressure: 3, 6, 10 bar
  • Maximum working temperature: 95(° C)
  • Designation of tanks: alternative energy systems, heating systems, hot water systems
  • Heat exchanger: lower
  • Heat exchanger type: spiral (helical) welded heat exchanger
  • Heat exchanger material: stainless steel, carbon steel
  • Heat transfer surface area: 3.3(m²)
  • Insulation: Yes
Quick order
Enter your phone number and
our manager will call you back
  • Specification
  • Description
  • Dimensions and weight
  • Equipment selection
  • Options
  • Delivery and payment
Volume 3000 l
Tank working pressure range 0 - 13 bar
Tank operating temperature range 0 - 95 ° C
Working pressure in the heat exchanger 3-16 bar
Maximum heating medium in the heat exchanger 200 ° C
Materials (edit) CSE — carbon steel with food-grade enamel interior
Heat exchanger / heater HHW— (heat exchanger helical welded) spiral (helical) welded heat exchanger
Connection Heating element connection Solar collector connection Solid fuel boiler connection Gas boiler connection Electric boiler connection
Accession flanged / threaded / clamped / welded; according to GOST, ISO, DIN standards
Insulation Soft polyurethane (40-200mm), rubber + removable leather / fabric cover
Corrosion protection Magnesium anode
Accommodation vertical / horizontal;
Support Adjustable / non-adjustable
Certification TU U 28.9-30521500-005-2017 ISO 9001
Model Volume, l Diameter, mm Height, mm
OPEKS-2-3000-CSE-HHW3,3.3L 3000 1360 2200

Accumulation tanks represent a vertical (or horizontal) welded structure, consisting of a cylindrical shell, upper and lower (left and right) elliptical bottoms, a fitting for supplying and removing the working medium and drainage of the system, as well as a fitting according to the project or at the request of the customer. Supports are welded to the lower bottom (shells - in horizontal design) for reliable installation on site.

Storage tanks are used as heat or cold accumulators, buffer tanks, water heaters. OPEKS -2 models are designed for: heating, accumulation of thermal energy in the form of hot water, hydraulic isolation of flows in the circuits of technological systems of industrial enterprises, hot water supply and heating systems, storage and transfer of excess heat received from the source (electric boiler, solid fuel boiler , heat pump, solar collectors, solar systems) with the ability to connect several sources of thermal energy.

  • increase in the service life of the heating system;
  • reduction of fuel consumption by 30-40%;
  • increase in the service life of the heating system;
  • reducing the risk of boiling a solid fuel boiler;
  • the ability to maintain a constant temperature;
  • combining different types of heat energy;
  • extension of the interval between boiler cleanings, easy installation into the existing heating system.

OPEKS-2-3000-CSE-HHW-L

Capacity characteristics Outlet diameter Unit rev 3000 l
A - Complete drainage of water 2 ″ mm 90
B - Incoming stream (bottom heat exchanger) 1 1⁄4 ″ mm 485
C - Return from the system 2 ″ mm 615
D - Outgoing stream (bottom heat exchanger) 1 1⁄4 ″ mm 910
E - Supply to the system 2 ″ mm 1755
F - Security group 2 ″ mm 2280
G - Technical water drain 1/2 ″ mm 455
H - Return to the boiler 2 ″ mm 465
I - Boiler feed 2 ″ mm 1755
T - temperature sensors
mm
L - Height
mm 2280
W - Width (Diameter)
mm 1560
Weight
Kg 405
Bottom heat exchanger characteristics Unit rev 3000
Square m 2 2.7
Volume l 15

Note.

The tank / boiler dimensions are based on the standard model with a working pressure of 6 bar. It is possible to manufacture non-standard models with other parameters according to the agreed drawing.

To select the required storage volume, it is possible to combine several tanks into a cascade.

The storage tank is selected for the previously selected heat source and is calculated in such a way that it can accumulate all the heat generated by this source, or for the consumer of which it should be provided with heat generated before the time of heat consumption by a low-power source.

The priority in the selection of the capacity will be the source if its power or the time of heat input is limited.

The priority in the selection of the capacity will be the consumer, if it is required to cover a given heat load in a certain time.
The additional volume of water formed during heating to the maximum temperature is ~ 3.5% of the nominal volume of the container.

  • vertical / horizontal placement;
  • security group;
  • level / temperature / pressure sensors;
  • thermoelectric heater;
  • heat exchanger;
  • insulation in the cold;
  • cathodic protection;
  • service;
  • inspection hatch; leather / fabric cover;
  • development of individual equipment *

Delivery

  • Pickup from a warehouse in Kiev - is free
  • New Mail - at the rates of the delivery service, at the rates of the delivery service, at the rates of the delivery service
  • SAT - at the rates of the delivery service
  • Deliveri - at the rates of the delivery service

Payment

  • Cashless payment with VAT
  • Online Privat24, Visa / MasterCard
Indirect heating boiler 3000 liters OPEKS23000CSEHHWL

All equipment catalog

Sorting
ApplyReset
Close
loading
loading