Gallery with project descriptions
Below on the page are the works performed by OPEKS ENERGOSYSTEMY.
Tying steam condensers in a confectionery factory. Steam plate condenser models PTA(GC)-26 with Yoshitake float type steam traps. Condensate cooler - model PTA(GL)-13 Steam temperature 150 C
Steam regulation system with emergency closing valve
Steam condensers with Yoshitake float traps based on PTA(GC)-51 models with PTA(GC)-30 condensate cooler
Water heater TRANTER GL-85 for the technical process at a manufacturing plant. Branch pipe diameter Du300. Power 8.5 MW.
Plot of plate coolers of circulating water in the production hall
Steam temperature control unit with motorized globe valve Clorius
Steam condensation unit in the form of MTP modular heating unit with LESER safety valves in the plant's energy department
Condensate removal unit using float-operated condensate traps as part of a steam-using plant
Modular heating point for technological process. Piping and receiver made of stainless steel
Heating substation of the ventilation system for the Hilton hotel. Based on a special model PTA(GC)-54 plate heat exchanger with a temperature difference between the water and propylene glycol circuits of 1C
Pasteurization plant for milk with heat carrier steam, which condenses in a brazed plate heat exchanger B12 SWEP
Individual heating point of a multi-apartment sectional residential building. MTP-ON model with control cabinet and frequency control of pumps
Ventilation unit for an administrative building. The total power of both heat exchangers is 3000 kW.
Tying the heat exchanger of the heating system, connection to the distribution manifold. Model PTA(GC)-16. Approximate power 400 kW.
Quarterly boiler house with a capacity of 20 MW. As part of the separating heat exchangers RTA (GX) -51 - 4 pcs, between the heat carrier from the boilers and the heating main with a unit capacity of 5 MW. Viessmann boilers
Plate heat exchangers of models PTA(GX)-26 and PTA(GL)-13 as part of a technological system
Ventilation and air conditioning system with water-propylene glycol separation heat exchangers in an office building. Heat exchangers model PTA(GX)-42
Heating unit for an administrative building. Power per heat exchanger 700 kW
Condensate pumping station based on Wilo electric circulation pumps with a 2000 l condensate collection tank.
Steam Compressor (Steam Ejector) for Cardboard and Paper Factory
Steam modular unit with a welded steam condenser with a power of 3.6 MW and a steam temperature of 200 C
Automated pumping stations for water supply Hydromaks with frequency converters in control cabinets manufactured by OPEKS for quarterly pumping stations
Pipes with milk thread for milk cooler based on heat exchanger PTA(GL)-8
High-capacity water supply pumping stations for quarterly pumping stations with stainless steel manifolds based on Wilo multistage pumps
Steam separators before shipment to customers. They are used to remove moisture from steam in steam systems, or to remove moisture from compressed air.
Modular automated steam unit with steam condensers based on plate heat exchangers model PTA(GL)-13 with 100% load redundancy. Power 800 kW per steam condenser
Spiral Heat Exchanger for Grain Wort for Distillery
Scraper type steam recovery unit for condensing polluted steam for poultry farm process
Hydraulic arrow for the boiler room
All-stainless heat exchangers model PTA(GL)-13 for the technological process at the Coca-Cola plant
A complex of equipment for the technological process at a brewery with a system of accounting and regulation
Steam condenser model PTA(GC)-51 with Viton gaskets, for steam condensation at a temperature of 180 C
ITP for a heating system in a modular design MTP-ON with a built-in magnetic sludge trap
Plate heat exchanger for alcohol cooling for cognac factory. Food-grade version, with a stainless steel plated carrier frame and milk thread spigots
Heating point of the office and shopping center. Plate heat exchangers model PTA(GC)-16 and PTA(GX)-26
Block-modular boiler house with a capacity of 350 kW
PTA(GL)-9 heat exchanger piping unit as a part of the boiler house
Manufacture and supply of pumping stations for the domestic water supply system based on Wilo pumps
Thermal substation for steam at a starch slurry plant with float-type condensate traps and steam condensers based on OPEKS plate heat exchangers of the PTA(GL)-13 model
Steam supply control system using a Clorius electric control valve as part of a steam modular heating substation
Supply of brazed plate heat exchangers SWEP model B427 for air conditioning system
Shipment of 6 plate heat exchangers model PTA(GX)-42 for central heating system
One of the heat points for the heating and ventilation system of a large shopping center. Wilo pumps, Danfoss control valves, PTA(GX)-26 heat exchangers
Automatic self-cleaning filter SAB F450 for continuous purification and filtration of water from open sources, before shipment
Water supply pumping station for an agricultural holding based on Grundfos multistage booster pumps. Parameters: head 60 m.a.c., flow 150 m3/h.
Shell-and-tube heat exchanger OPEKS-3-LL for technological process with polluted media. Power 560 kW.
Air heater with superheated water
Storage tank with a volume of 2000 l with a pipe DN300, a closed flange for revision
Boiler of indirect heating with a volume of 3000 l with built-in serpentine water heater and electric heater
Flash steam separator for high temperature condensate heat recovery system
Water cooling system with direct temperature controller and PTA(GL)-8 plate heat exchangers with 100% redundancy
Utilizer of heat of products of combustion of a gas copper. Gas cooling is carried out by water circulating in heat exchange plates
Manufacture of a shell-and- tube heat exchanger OPEKS-3-PH for heating water in the pool completely from stainless steel
TRANTER Supermax All-Stainless Welded Heat Exchanger for Process Refinery
Manufacture of the OPEKS-3-SC shell and tube steam condenser in the OPEKS workshop, before shipment to the customer
ITP with modular blocks for hot water supply (DHW) and heating in the basement of a residential building
Installation and piping of plate heat exchangers OPEKS PTA(GX)-51 at an industrial plant
Modular block MTP-GV of the hot water supply system with a water meter section and a control cabinet
Finished plate heat exchangers manufactured by OPEKS Power systems of the PTA(GX)-42 model range before shipment for installation in the heating substation of an administrative building
Installation of RTA collapsible plate heat exchangers at one of the industrial enterprises
Spiral heat exchanger before shipment to the customer - the chemical industry
Installation of steam condensers PTA(GC)-51 with a capacity of 2200 kW each in the steam boiler room of the enterprise instead of the old shell-and-tube condensers. Float Type Steam Traps
Storage tanks for hot water storage and ice water storage in a warehouse before shipment to customers
Installed automatic filters F450 for continuous filtration of recycled water for the cooling system of the industrial enterprise taken from the lake. Water consumption 2000 m3/h
Clorius 3-way control valve Du350 for quarterly hot water boiler
Brazed heat exchanger SWEP V80x40 - an evaporator for a refrigeration machine. The design includes a flow distributor through the evaporator channels to prevent freezing
Hydromaks fire extinguishing pump stations manufactured by OPEKS for a construction company in stock before shipment
Modular block of the heating system MTP-ON in one of the zones of the heating point of the residential complex
Yoshitake TB-20F inverted bowl steam trap in stock before shipping to customer. Condensate flow rate up to 300 kg/h, operating pressure up to 1.6 MPa, temperature up to 220C
Heating substation of a large shopping and office center with heat exchangers РТА(GX)-26 for the ventilation system
Make-up unit for a heating system of a residential building with make-up pumps before shipment to the customer
ShU control cabinet with Siemens controller, installed on the MTP steam unit with a shell-and-tube steam condenser
Steam metering unit on the steam block manufactured by OPEKS for a boiler house of an industrial enterprise
Plate heat exchanger PTA(GX)-100 with pipe diameter DN200 is awaiting shipment at the OPEKS production
Yoshitake TSF-11F float steam trap in stock before shipping to the customer. Condensate flow rate up to 3000 kg/h, operating pressure up to 2.1 MPa, temperature up to 220 C
Modular unit MTP-OZ for a heating system according to a dependent scheme
The observation window of the Japanese company Yoshitake for visual diagnostics of the operation of the steam trap
Yoshitake TSF-8 float steam trap in stock before shipping to customer. Condensate flow rate up to 1800 kg/h, operating pressure up to 2.1 MPa, temperature up to 220C
Japanese company Yoshitake GD-30 direct acting pressure reducing valve for steam with brass body before shipment to the customer. Can also be with cast iron and stainless steel body
Condensate pumping station manufactured by OPEKS based on a Yoshitake PF-7000 mechanical pump with a live steam pressure of 8 barg and a condensate flow rate of up to 8000 kg/h
Danfoss differential pressure regulator as part of a modular heating system unit according to an independent MTP-ON scheme
Boiler room of an industrial enterprise with a PTA(GC)-12 heat exchanger for hot water heating and an accumulator tank for its storage
Hydraulic module for air conditioning system with 100 l storage tank and control cabinet
Heating point in a modular-block design type MTP-ON-4000 of a heating system with 50% redundancy of heat exchangers PTA (GX) -42 for a textile factory and ITP for a DHW system based on heat exchangers РТА (GL) -8
SWEP B15x20 brazed plate heat exchanger for warehouse chiller
Separating plate heat exchangers model PTA(GX)-42 at a quarterly boiler house with a capacity of 5.4 MW
Expansion membrane tanks for a heating system in a shopping center
Steam traps for the removal of condensate from exhaust steam during the paper production process in a pulp and paper mill
Modular heat substation type MTP-ON for heating water for the technological process at the TetraPak factory with a PTA(GL)-13 heat exchanger and a Grundfos pump
Plate heat exchangers PTA(GX)-51 for heating sunflower oil. Pipes DN150 along the oil circuit are made of stainless steel
Thermal substation of the heating and ventilation system of a shopping and office center based on heat exchangers of the PTA (GX)-42 model, with a unit capacity of up to 5000 kW with Wilo circulation pumps
Thermal substation of the heating system of the lower zone of a multi-storey residential building based on PTA(GC)-16 heat exchangers
Cooling of circulating water of technological equipment based on plate heat exchangers. Cooling water - cooling tower water
MTP-ON modular block control cabinet
Process cooling system based on PTA(GX)-100 heat exchangers
Cold storage tanks for storing ice water with a capacity of 7000 l, made of AISI304 stainless steel with 100 mm thermal insulation. Installed as part of the data center air conditioning system
Cooling system for circulating water using separating heat exchangers for a metallurgical plant
Lamellar heaters OPEKS РТА(GX)-91 of the heating system for the central heating point. Power of one unit 6.5 MW
Three-circuit plate combicooler model PTA(GX)-26, cooler for fresh water and diesel fuel for a sea tug. Complies with ABS, GL, LRS, NK, BV, DNV, RINA, KR, CCS and RS marine certifications
Cooling system for circulating water of an oxygen-converter shop of a metallurgical plant using separating heat exchangers with a pipe diameter of DN500
Cooling system for circulating water for a metallurgical plant. JUMBO TRANTER GL-430 series heat exchangers
Heating system heat exchangers PTA(GX)-51 with 100% power reserve and DHW heat exchanger PTA(GL)-13.