Gallery with project descriptions
Below on the page are the works performed by OPEKS ENERGOSYSTEMY.

Tying steam condensers in a confectionery factory. Steam plate condenser models PTA(GC)-26 with Yoshitake float type steam traps. Condensate cooler - model PTA(GL)-13 Steam temperature 150 C

Steam regulation system with emergency closing valve

Steam condensers with Yoshitake float traps based on PTA(GC)-51 models with PTA(GC)-30 condensate cooler

Water heater TRANTER GL-85 for the technical process at a manufacturing plant. Branch pipe diameter Du300. Power 8.5 MW.

Plot of plate coolers of circulating water in the production hall

Steam temperature control unit with motorized globe valve Clorius

Steam condensation unit in the form of MTP modular heating unit with LESER safety valves in the plant's energy department

Condensate removal unit using float-operated condensate traps as part of a steam-using plant

Modular heating point for technological process. Piping and receiver made of stainless steel

Heating substation of the ventilation system for the Hilton hotel. Based on a special model PTA(GC)-54 plate heat exchanger with a temperature difference between the water and propylene glycol circuits of 1C

Pasteurization plant for milk with heat carrier steam, which condenses in a brazed plate heat exchanger B12 SWEP

Individual heating point of a multi-apartment sectional residential building. MTP-ON model with control cabinet and frequency control of pumps

Ventilation unit for an administrative building. The total power of both heat exchangers is 3000 kW.

Tying the heat exchanger of the heating system, connection to the distribution manifold. Model PTA(GC)-16. Approximate power 400 kW.

Quarterly boiler house with a capacity of 20 MW. As part of the separating heat exchangers RTA (GX) -51 - 4 pcs, between the heat carrier from the boilers and the heating main with a unit capacity of 5 MW. Viessmann boilers

Plate heat exchangers of models PTA(GX)-26 and PTA(GL)-13 as part of a technological system

Ventilation and air conditioning system with water-propylene glycol separation heat exchangers in an office building. Heat exchangers model PTA(GX)-42

Heating unit for an administrative building. Power per heat exchanger 700 kW

Condensate pumping station based on Wilo electric circulation pumps with a 2000 l condensate collection tank.

Steam Compressor (Steam Ejector) for Cardboard and Paper Factory

Steam modular unit with a welded steam condenser with a power of 3.6 MW and a steam temperature of 200 C

Automated pumping stations for water supply Hydromaks with frequency converters in control cabinets manufactured by OPEKS for quarterly pumping stations

Pipes with milk thread for milk cooler based on heat exchanger PTA(GL)-8

High-capacity water supply pumping stations for quarterly pumping stations with stainless steel manifolds based on Wilo multistage pumps

Steam separators before shipment to customers. They are used to remove moisture from steam in steam systems, or to remove moisture from compressed air.

Modular automated steam unit with steam condensers based on plate heat exchangers model PTA(GL)-13 with 100% load redundancy. Power 800 kW per steam condenser

Spiral Heat Exchanger for Grain Wort for Distillery

Scraper type steam recovery unit for condensing polluted steam for poultry farm process

Hydraulic arrow for the boiler room

All-stainless heat exchangers model PTA(GL)-13 for the technological process at the Coca-Cola plant

A complex of equipment for the technological process at a brewery with a system of accounting and regulation

Steam condenser model PTA(GC)-51 with Viton gaskets, for steam condensation at a temperature of 180 C

ITP for a heating system in a modular design MTP-ON with a built-in magnetic sludge trap

Plate heat exchanger for alcohol cooling for cognac factory. Food-grade version, with a stainless steel plated carrier frame and milk thread spigots

Heating point of the office and shopping center. Plate heat exchangers model PTA(GC)-16 and PTA(GX)-26

Block-modular boiler house with a capacity of 350 kW

PTA(GL)-9 heat exchanger piping unit as a part of the boiler house

Manufacture and supply of pumping stations for the domestic water supply system based on Wilo pumps

Thermal substation for steam at a starch slurry plant with float-type condensate traps and steam condensers based on OPEKS plate heat exchangers of the PTA(GL)-13 model

Steam supply control system using a Clorius electric control valve as part of a steam modular heating substation

Supply of brazed plate heat exchangers SWEP model B427 for air conditioning system

Shipment of 6 plate heat exchangers model PTA(GX)-42 for central heating system

One of the heat points for the heating and ventilation system of a large shopping center. Wilo pumps, Danfoss control valves, PTA(GX)-26 heat exchangers

Automatic self-cleaning filter SAB F450 for continuous purification and filtration of water from open sources, before shipment

Water supply pumping station for an agricultural holding based on Grundfos multistage booster pumps. Parameters: head 60 m.a.c., flow 150 m3/h.

Shell-and-tube heat exchanger OPEKS-3-LL for technological process with polluted media. Power 560 kW.

Air heater with superheated water

Storage tank with a volume of 2000 l with a pipe DN300, a closed flange for revision

Boiler of indirect heating with a volume of 3000 l with built-in serpentine water heater and electric heater

Flash steam separator for high temperature condensate heat recovery system

Water cooling system with direct temperature controller and PTA(GL)-8 plate heat exchangers with 100% redundancy

Utilizer of heat of products of combustion of a gas copper. Gas cooling is carried out by water circulating in heat exchange plates

Manufacture of a shell-and- tube heat exchanger OPEKS-3-PH for heating water in the pool completely from stainless steel

TRANTER Supermax All-Stainless Welded Heat Exchanger for Process Refinery

Manufacture of the OPEKS-3-SC shell and tube steam condenser in the OPEKS workshop, before shipment to the customer

ITP with modular blocks for hot water supply (DHW) and heating in the basement of a residential building

Installation and piping of plate heat exchangers OPEKS PTA(GX)-51 at an industrial plant

Modular block MTP-GV of the hot water supply system with a water meter section and a control cabinet

Finished plate heat exchangers manufactured by OPEKS Power systems of the PTA(GX)-42 model range before shipment for installation in the heating substation of an administrative building

Installation of RTA collapsible plate heat exchangers at one of the industrial enterprises

Spiral heat exchanger before shipment to the customer - the chemical industry

Installation of steam condensers PTA(GC)-51 with a capacity of 2200 kW each in the steam boiler room of the enterprise instead of the old shell-and-tube condensers. Float Type Steam Traps

Storage tanks for hot water storage and ice water storage in a warehouse before shipment to customers

Installed automatic filters F450 for continuous filtration of recycled water for the cooling system of the industrial enterprise taken from the lake. Water consumption 2000 m3/h

Clorius 3-way control valve Du350 for quarterly hot water boiler

Brazed heat exchanger SWEP V80x40 - an evaporator for a refrigeration machine. The design includes a flow distributor through the evaporator channels to prevent freezing

Hydromaks fire extinguishing pump stations manufactured by OPEKS for a construction company in stock before shipment

Modular block of the heating system MTP-ON in one of the zones of the heating point of the residential complex

Yoshitake TB-20F inverted bowl steam trap in stock before shipping to customer. Condensate flow rate up to 300 kg/h, operating pressure up to 1.6 MPa, temperature up to 220C

Heating substation of a large shopping and office center with heat exchangers РТА(GX)-26 for the ventilation system

Make-up unit for a heating system of a residential building with make-up pumps before shipment to the customer

ShU control cabinet with Siemens controller, installed on the MTP steam unit with a shell-and-tube steam condenser

Steam metering unit on the steam block manufactured by OPEKS for a boiler house of an industrial enterprise

Plate heat exchanger PTA(GX)-100 with pipe diameter DN200 is awaiting shipment at the OPEKS production

Yoshitake TSF-11F float steam trap in stock before shipping to the customer. Condensate flow rate up to 3000 kg/h, operating pressure up to 2.1 MPa, temperature up to 220 C

Modular unit MTP-OZ for a heating system according to a dependent scheme

The observation window of the Japanese company Yoshitake for visual diagnostics of the operation of the steam trap

Yoshitake TSF-8 float steam trap in stock before shipping to customer. Condensate flow rate up to 1800 kg/h, operating pressure up to 2.1 MPa, temperature up to 220C

Japanese company Yoshitake GD-30 direct acting pressure reducing valve for steam with brass body before shipment to the customer. Can also be with cast iron and stainless steel body

Condensate pumping station manufactured by OPEKS based on a Yoshitake PF-7000 mechanical pump with a live steam pressure of 8 barg and a condensate flow rate of up to 8000 kg/h

Danfoss differential pressure regulator as part of a modular heating system unit according to an independent MTP-ON scheme

Boiler room of an industrial enterprise with a PTA(GC)-12 heat exchanger for hot water heating and an accumulator tank for its storage

Hydraulic module for air conditioning system with 100 l storage tank and control cabinet

Heating point in a modular-block design type MTP-ON-4000 of a heating system with 50% redundancy of heat exchangers PTA (GX) -42 for a textile factory and ITP for a DHW system based on heat exchangers РТА (GL) -8

SWEP B15x20 brazed plate heat exchanger for warehouse chiller

Separating plate heat exchangers model PTA(GX)-42 at a quarterly boiler house with a capacity of 5.4 MW

Expansion membrane tanks for a heating system in a shopping center

Steam traps for the removal of condensate from exhaust steam during the paper production process in a pulp and paper mill

Modular heat substation type MTP-ON for heating water for the technological process at the TetraPak factory with a PTA(GL)-13 heat exchanger and a Grundfos pump

Plate heat exchangers PTA(GX)-51 for heating sunflower oil. Pipes DN150 along the oil circuit are made of stainless steel

Thermal substation of the heating and ventilation system of a shopping and office center based on heat exchangers of the PTA (GX)-42 model, with a unit capacity of up to 5000 kW with Wilo circulation pumps

Thermal substation of the heating system of the lower zone of a multi-storey residential building based on PTA(GC)-16 heat exchangers

Cooling of circulating water of technological equipment based on plate heat exchangers. Cooling water - cooling tower water

MTP-ON modular block control cabinet

Process cooling system based on PTA(GX)-100 heat exchangers

Cold storage tanks for storing ice water with a capacity of 7000 l, made of AISI304 stainless steel with 100 mm thermal insulation. Installed as part of the data center air conditioning system

Cooling system for circulating water using separating heat exchangers for a metallurgical plant

Lamellar heaters OPEKS РТА(GX)-91 of the heating system for the central heating point. Power of one unit 6.5 MW

Three-circuit plate combicooler model PTA(GX)-26, cooler for fresh water and diesel fuel for a sea tug. Complies with ABS, GL, LRS, NK, BV, DNV, RINA, KR, CCS and RS marine certifications

Cooling system for circulating water of an oxygen-converter shop of a metallurgical plant using separating heat exchangers with a pipe diameter of DN500

Cooling system for circulating water for a metallurgical plant. JUMBO TRANTER GL-430 series heat exchangers

Heating system heat exchangers PTA(GX)-51 with 100% power reserve and DHW heat exchanger PTA(GL)-13.