vendor code | Heat exchange area, m 2 | Compatible with QE tanks |
ES 01 | 0.75 | 200 ÷ 5000 |
ES 02 | 1.30 | 200 ÷ 5000 |
ES 03 | 1.80 | 200 ÷ 5000 |
ES 04 | 2.30 | 300 ÷ 5000 |
ES 05 | 2.60 | 500 ÷ 5000 |
ES 06 | 3.20 | 500 ÷ 5000 |
ED 01 | 4.50 | 800 ÷ 5000 |
ED 02 | 5.30 | 800 ÷ 5000 |
ED 03 | 6.30 | 1500 ÷ 5000 |
* For more detailed information on heat exchangers, see the catalog. |
Application | Hot potable water is accumulated and heated by one or more heat exchangers. The heating area can be selected depending on the needs and the heat sources used, for example, from solar collectors, a boiler, heat pumps, etc. |
Execution | Made of high quality S235JR EN10025 carbon steel, assembled and welded by automatic welding. HEAT EXCHANGER art. ES copper finned tubular heat exchanger with single helical coil, fixed on a Ø300 mm flange. HEAT EXCHANGER art. ED copper finned tubular heat exchanger with double helical coil, fixed on Ø300 mm flange. |
Anti-corrosion coating | Art. QE 200 ÷ 3000 internal anti-corrosion coating (enamel) obtained by high-temperature treatment in an oven at 860 ° C. Fully complies with the requirements for drinking water according to DM 174/2004 (Italian standards) and the CEE directive 76/893. Art. QE 4000 ÷ 5000 internal anti-corrosion coating made of CERAMPLAST on a micro-ceramic base, used for work in aggressive environments with high temperatures, in installations with solar collectors, with a sharp increase in temperature, in order to avoid the spread of legionella bacteria. Fully complies with the requirements for drinking water according to DM 174/2004 (Italian standards) and the CEE directive 76/893. Maximum operating temperature 110 ° C. |
Cathodic protection | Art. QE threaded magnesium anode. Art. QE-PLUS electronic anode for permanent cathodic protection. |
Insulation and type of outer cover | Art. QE removable casing made of rigid polyurethane for mod. 1000 liters or less, and flexible polyurethane 100 mm thick for all others, PVC outer cover with zip and thermal cover, Art. QE-PLUS removable rigid polyurethane casing, PVC outer cover with zip and thermal cover. |
Certificates | Complies with directive 97/23 / CE Art. 3 - Part 3. |
Model | 200 | 300 | 500 | 800 | 1000 | 1500 | 2000 | 2500 | 3000 | 4000 | 5000 | ||
Volume | l | 185 | 295 | 500 | 795 | 920 | 1435 | 1980 | 2605 | 2910 | 3710 | 4945 | |
d | Diameter without insulation | mm | 450 | 550 | 650 | 800 | 800 | 950 | 1100 | 1250 | 1250 | 1400 | 1600 |
D | Insulated diameter | mm | 550 | 650 | 750 | 900 | 900 | 1150 | 1300 | 1450 | 1450 | 1600 | 1800 |
HT | Height | mm | 1360 | 1430 | 1710 | 1800 | 2050 | 2390 | 2430 | 2500 | 2750 | 2800 | 2830 |
FL1 | S1 inspection hatch diameter | mm | 220 × 300 | 400 × 480 | |||||||||
FL2 | Diameter of the inspection hatch S2 | mm | 220 × 300 | ||||||||||
FL3 | S3 inspection hatch diameter | mm | - | - | - | 220 × 300 | |||||||
K | Maximum tilt height | mm | 1468 | 1561 | 1853 | 1984 | 2130 | 2653 | 2761 | 2899 | 2951 | 3245 | 3372 |
Weight, 6 bar | Kg | - | - | - | - | - | 220 | 260 | 300 | 325 | 480 | 560 | |
Weight, 8 bar | Kg | 65 | 75 | 90 | 130 | 165 | 280 | 330 | 385 | 420 | 585 | 690 | |
Weight, 10 bar | Kg | 80 | 95 | 115 | 170 | 190 | 340 | 405 | 470 | 510 | 695 | 820 | |
Connections | |||||||||||||
E | Cold water inlet | G1 "¼ | G1 "¼ | G1 "¼ | G1 "½ | G1 "½ | G2 " | G2 " | G2 "½ | G2 "½ | G3 " | G3 " | |
U | Hot water outlet | G1 "¼ | G1 "¼ | G1 "¼ | G1 "¼ | G1 "¼ | G2 " | G2 " | G2 "½ | G2 "½ | G3 " | G3 " | |
RC | Recirculation | G1 "¼ | G1 "¼ | G1 "¼ | G1 "½ | G1 "½ | G2 " | G2 " | G2 "½ | G2 "½ | G3 " | G3 " | |
RE | Electric heating element | G1 "¼ | G1 "¼ | G1 "¼ | G1 "½ | G1 "½ | G1 "½ | G1 "½ | G2 " | G2 " | G2 " | G2 " | |
S | Draining | G1 "¼ | G1 "¼ | G1 "¼ | G1 "¼ | G1 "¼ | G1 "¼ | G1 "¼ | G1 "¼ | G1 "¼ | G1 "¼ | G1 "¼ | |
A | Magnesium anode | G1 "¼ | G1 "¼ | G1 "¼ | G1 "½ | G1 "½ | G1 "½ | G1 "½ | G1 "½ | G1 "½ | G1 "½ | G1 "½ | |
T | Thermometer / thermostat | G½ " | G½ " | G½ " | G½ " | G½ " | G½ " | G½ " | G½ " | G½ " | G½ " | G½ " | |
AE | Electronic anode | - | - | - | - | G½ " | G½ " | G½ " | G½ " | G½ " | G½ " | G½ " | |
So | Sensor | G½ " | G½ " | G½ " | G½ " | G½ " | G½ " | G½ " | G½ " | G½ " | G½ " | G½ " | |
Technical details | |||||||||||||
PE | Maximum working pressure of the tank | bar | eight | eight | eight | eight | eight | 6 | 6 | 6 | 6 | 6 | 6 |
PC | Tank test pressure | bar | 12 | 12 | 12 | 12 | 12 | nine | nine | nine | nine | nine | nine |
Maximum working pressure of the heat exchanger | bar | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 12 | |
Heat exchanger test pressure | bar | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 16 | |
TE | Max. working temperature | ° C | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 |