vendor code | QA | QA-PLUS | QA-F | QA / F-PLUS | XM / F | XM / F-PLUS | ||||||||
Maximum operating temperature 65 ° C | 100 ° C | |||||||||||||
Insulation | flexible polyurethane | removable polyurethane | flexible polyurethane | removable polyurethane | flexible polyurethane | removable polyurethane | ||||||||
Protection | magnesium anode | electronic anode | magnesium anode | electronic anode | ||||||||||
Flange | No | No | there is | there is | there is | there is | ||||||||
Pressure | 8 bar | 10 bar | 8 bar | 10 bar | 6 bar | 8 bar | 10 bar | 6 bar | 8 bar | 10 bar | 6 bar | 8 bar | 6 bar | 8 bar |
Application | The accumulation of hot drinking water, water heating takes place in a heat exchanger outside the tank, using traditional or alternative energy sources, heat pumps, heat recovery systems, etc. |
Execution | Art. QA - QA / F: Made of high quality S235JR EN10025 carbon steel. Art. XM / F: made of AISI 316 Ti stainless steel sheet, assembled and welded by automatic welding. |
Anti-corrosion coating | Art. QA - QA / F: enamelled anticorrosive coating with PTFE fluoropolymers. (Teflon), suitable for use and consumption of hot potable water in accordance with directives 98/83 CE and DL 31/2001. Art. XM / F: Completed after welding: weld passivation and surface etching. |
Cathodic protection | Art. QA - QA / F: threaded magnesium anode. Art. QA / F-PLUS: electronic anode for permanent cathodic protection. |
Insulation and type of outer cover | Art. QA, QA / F and XM / F: flexible open cell polyurethane and PVC outer cover with zipper. Art. QA / F-PLUS and XM / F-PLUS: removable polyurethane casing and outer PVC cover with zipper. |
Certificates | Complies with directive 97/23 / CE Art. 3 - Part 3 |
Model | 200 | 300 | 500 | 800 | 1000 | 1500 | 2000 | 2500 | 3000 | 4000 | 5000 | 6000 | 8000 | 10000 | ||
Volume | l | 194 | 298 | 509 | 765 | 924 | 1468 | 2016 | 2664 | 2970 | 3839 | 5079 | 5950 | 7705 | 8715 | |
d | Diameter without insulation | mm | 450 | 550 | 650 | 800 | 800 | 950 | 1100 | 1250 | 1250 | 1400 | 1600 | 1600 | 1800 | 1900 |
D | Insulated diameter | mm | 550 | 650 | 750 | 900 | 900 | 1050 | 1200 | 1350 | 1350 | 1500 | 1700 | 1700 | 1900 | 2000 |
HT | Height | mm | 1460 | 1490 | 1790 | 1800 | 2130 | 2390 | 2430 | 2500 | 2750 | 2800 | 2830 | 3335 | 3410 | 3470 |
L | Length (horizontal design) | mm | 1420 | 1460 | 1670 | 1860 | 2210 | 2320 | 2390 | 2460 | 2705 | 2800 | 2890 | - | - | - |
IS | Distance between supports (horizontal version) | mm | 840 | 840 | 1090 | 1010 | 1230 | 1510 | 1510 | 1470 | 1720 | 1720 | 1720 | - | - | - |
FL | Inspection hatch diameter | mm | 220 × 300 | 300 × 380 | 350 × 430 | 400 × 480 | ||||||||||
K | Maximum tilt height | mm | 1550 | 1625 | 1960 | 1990 | 2230 | 2550 | 2460 | 2550 | 2780 | 2860 | 2920 | 3450 | 3550 | 3620 |
The weight | Kg | 58 | 68 | 88 | 120 | 160 | 205 | 260 | 310 | 360 | 410 | 510 | 635 | 910 | 975 | |
Connections | ||||||||||||||||
E | Cold water inlet | G1¼ '' | G1¼ '' | G1¼ '' | G1½ '' | G1½ '' | G2 '' | G2 '' | G2½ '' | G2½ '' | G3 '' | G3 '' | G3 '' | G3 '' | G3 '' | |
U | Hot water outlet | G1¼ '' | G1¼ '' | G1¼ '' | G1¼ '' | G1¼ '' | G2 '' | G2 '' | G2½ '' | G2½ '' | G3 '' | G3 '' | G3 '' | G3 '' | G3 '' | |
RC | Recirculation | G1¼ '' | G1¼ '' | G1¼ '' | G1½ '' | G1½ '' | G2 '' | G2 '' | G2½ '' | G2½ '' | G3 '' | G3 '' | G3 '' | G3 '' | G3 '' | |
RE | Electric heating element | G1¼ '' | G1¼ '' | G1¼ '' | G1½ '' | G1½ '' | G1½ '' | G1½ '' | G2 '' | G2 '' | G2 '' | G2 '' | G2 '' | G2 '' | G2 '' | |
S | Draining | G1¼ '' | G1¼ '' | G1¼ '' | G1¼ '' | G1¼ '' | G1¼ '' | G1¼ '' | G1¼ '' | G1¼ '' | G1¼ '' | G1¼ '' | G1¼ '' | G1'¼ '' | G1¼ '' | |
A | Magnesium anode | G1¼ '' | G1¼ '' | G1¼ '' | G1½ '' | G1½ '' | G1½ '' | G1½ '' | G1½ '' | G1½ '' | G1½ '' | G1½ '' | G1½ '' | G1½ '' | G1½ '' | |
So | Sensor hole | G½ '' | G½ '' | G½ '' | G½ '' | G½ '' | G½ '' | G½ '' | G½ '' | G½ '' | G½ '' | G½ '' | G½ '' | G½ '' | G½ '' | |
T | Thermometer / thermostat | G½ '' | G½ '' | G½ '' | G½ '' | G½ '' | G½ '' | G½ '' | G½ '' | G½ '' | G½ '' | G½ '' | G½ '' | G½ '' | G½ '' | |
AE | Electronic anode | - | - | - | - | G½ '' | G½ '' | G½ '' | G½ '' | G½ '' | G½ '' | G½ '' | G½ '' | G½ '' | G½ '' | |
AS | Conn. for heat exchanger | G1 '' | G1 '' | G1 '' | G1 '' | G1 '' | - | - | - | - | - | - | - | - | - | |
Technical details | ||||||||||||||||
PE | Maximum working pressure | bar | eight | eight | eight | eight | eight | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 |
PC | Test pressure | bar | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 12 |
TE | Continuous working temperature (QA-QA / F) | ° C | 65 | 65 | 65 | 65 | 65 | 65 | 65 | 65 | 65 | 65 | 65 | 65 | 65 | 65 |
TE | Peak temperature (QA-QA / F) | ° C | 81 | 81 | 81 | 81 | 81 | 81 | 81 | 81 | 81 | 81 | 81 | 81 | 81 | 81 |
TE | Maximum operating temperature (XM / F) | ° C | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 |
Delivery
- Pickup from a warehouse in Kiev - is free
- New Mail - at the rates of the delivery service, at the rates of the delivery service, at the rates of the delivery service
- SAT - at the rates of the delivery service
- Deliveri - at the rates of the delivery service
Payment
- Cashless payment with VAT
- Online Privat24, Visa / MasterCard