  • Manufacturer: Yoshitake
  • Material: cast bronze, fluoroplastic, stainless steel
Quick order
Enter your phone number and
our manager will call you back
  • Specifications
  • Description
  • Dimensions and weight
  • Chart
  • Delivery and payment

The temperature controller is a self-acting device that automatically controls the vapor / liquid flow depending on changes in the temperature of the cooled / heated medium and maintains the temperature of this medium at a constant level.

The automatic temperature controller does not require a power supply, so it continues to operate even during a power outage.

No electrical components required, temperature setting is done by turning the knob.

Frame

Parameter name Meaning
Model OB-30 OB-30U OB-31 OB-31U
Appointment For heating For cooling
Application Steam, hot water Cold water, refrigerant
Max. pressure 1.0 MPa (1.7 MPa for hot water) 1.7 MPa
Max. differential pressure 1.0 MPa
Leaking valve seat No more than 0.05% of the nominal flow
Max. temperature 185 ° C
Material Frame Cast bronze
Valve plug Fluoroplastic
Valve seat Stainless steel
Compound Threaded JIS Rc Threaded (split coupling) JIS Rc Threaded JIS Rc Threaded (split coupling) JIS Rc

Sensor

Medium to be heated Cold and hot water, oil, liquid
Medium to be cooled
Max. pressure 1.0 MPa
Material Thermal balloon Copper tube (nickel plated or chrome plated) *
Capillary Copper tube
Capillary. a tube Stainless steel
Std. capillary length 2 m
Compound Threaded JIS Rc
  • Available with a temperature sleeve (stainless steel).
  • If the spring is connected to the chamber, the bulb sleeve is not needed.
  • Available with 3 or 5 m capillary tube.

Temperature setting range

Setting range temp. (° C) Maintained pace. (° C)
0-35 75
25-70 110
40-100 140
60-130 170
70-150 190
  • The term withstand temperature refers to the maximum temperature at which the bellows can withstand internal pressure.
  • The maximum operating temperature of the bulb for cooling purposes is 100 ° C.
  • The model with a red handle is for heating, with a blue handle for cooling. You can determine their purpose at a glance.
  • Excellent durability, high tightness thanks to the locking mechanism made of stainless steel and fluoroelastomer.
  • The single valve and balancing bellows design provides stable temperature control regardless of inlet pressure fluctuations.
  • It is easy to change the characteristics of the regulator by simply replacing the body and the thermocylinder.
  • Wide temperature setting range, has many uses.
  • The bulb is suitable for heating and cooling purposes, and is common to all sizes (15 to 25A). It is possible to select a model only for the temperature control range.
  • Easy setting of the starting temperature by means of a knob.

Hull (ОВ-30 ∙ 31)

Nom. the size d OB-30-31
L Body weight
15A Rc 1/2 75 2.1
20A Rc 3/4 80 2.2
25A Rc 1 90 2.4

схема корпуса (ОВ-30∙31)

Case (ОВ-30U ∙ 31U)

Nom. the size d OB-30U-31U
L Body weight
15A Rc 1/2 160 3.1
20A Rc 3/4 160 3.1
25A Rc 1 160 3.1

схема корпуса ОВ-30U∙31U

• Sensor (common for OB-30 • 31 • 30U • 31U)

Capillary tube length 2m
The weight 0.6 kg

графики подбора Yoshitake OB-30, 30U OB-31, 31U

How to use the steam chart
When selecting the nominal size of the temperature controller at inlet pressure (P1), outlet pressure (P2) and steam flow rate of 0.2 MPa, 0.15 MPa and 20 kg / h, respectively, first find the point of intersection (a) of the pressure lines on inlet 0.2 MPa and outlet pressure 0.15 MPa. From this point (a) draw a line down to the intersection with the line corresponding to the flow rate of 20 kg / h — point of intersection (b). Since this intersection point (b) lies between nominal sizes 15A and 20A, choose the larger of the two, 20A.
* The flow chart is for reference.

How to use a water chart
When selecting the nominal size of the temperature controller with an inlet pressure, outlet pressure and flow rate of 0.3 MPa, 0.15 MPa and 1 m3 / h, respectively, first find the intersection point (a) of the differential pressure lines (ΔP) 0.15 MPa (0.3 MPa - 0.15 MPa) and a flow rate of 1 m3 / h. Since this intersection point (a) lies between dimensions 15A and 20A, choose the larger of the two, 20A.
• If using model OB-30 or OB-30U and the medium is hot water, use the selection chart above.
* The flow chart is for reference.

Delivery

  • Pickup from a warehouse in Kiev - is free
  • New Mail - at the rates of the delivery service, at the rates of the delivery service, at the rates of the delivery service
  • SAT - at the rates of the delivery service
  • Deliveri - at the rates of the delivery service

Payment

  • Cashless payment with VAT
  • Online Privat24, Visa / MasterCard
Temperature controller Yoshitake OB30 30U OB31 31U

All equipment catalog

Sorting
ApplyReset
Close
loading
loading