loading

Solenoid valve Yoshitake DP-200, 200-N DP-200F, 200F-N

Solenoid valve Yoshitake DP200 200N DP200F 200FNSolenoid valve Yoshitake DP200 200N DP200F 200FN
in stock
Price: specify

Quantity

Total

specify

  • Manufacturer: Yoshitake
  • Max. operating pressure: 1.0 MPa
  • Liquid temperature: 5-60 °C
  • Material: cast bronze, nitrile butadiene rubber
Quick order
Enter your phone number and
our manager will call you back
  • Specifications
  • Description
  • Dimensions and weight
  • Chart
  • Delivery and payment
Parameter name Meaning
Model Norm. closed DP-200 DP-200-N DP-200F DP-200F-N
Nominal size 10-50A 15-50A
Design Membrane type, pilot
Application Cold and hot water, air, nitrogen, carbon dioxide (dry), argon, oil (no more than 20 cSt: equivalent of kerosene or light oil products)
Operating pressure 0-1.0 MPa (does not work during evacuation)
Min. differential pressure 0 MPa (requires at least 0.1 MPa if the coil is facing to the side)
Permitted. valve seat leak Absent (visually by pressure gauge)
Temperature range 5-60 ° C (freezing not allowed)
Pace. surrounded Wednesday No more than 50 ° C (freezing is not allowed)
Installation position Vertical or horizontal installation (within 90 ° of the coil position vertically upwards)
Material Frame Cast bronze Cast bronze (NPb finish) Cast bronze Cast bronze (NPb finish)
Valve
Membrane Nitrile butadiene rubber
Compound JIS Rc Threaded Connection Flange connection JIS 10K FF

Available with FPM diaphragm. Max. temperature: 90 ° C (only for DP-200, DP-200F)

Coil Specifications

Rated voltage Change voltage AC 100/200 V with winding selection Change voltage AC 110/220 V with choice of winding
50/60 Hz total
Nominal size 10-50A
Permissible fluctuations Rated voltage: -5% to + 10%
Rated current 0.42 / 0.21 A 0.38 / 0.19 A
Starting current 1.64 / 0.82 A 1.48 / 0.74 A
Insulation class Insulation class H
Protective structure Dust-proof and splash-proof
Degree of protection IP64 (JISC0920)
Insulation resistance Not less than 50 MOhm at 500 V
Withstand voltage 1500 V / min
Removable leads Conduit G 1/2 (CTG 16)

* Available with terminal box.

The solenoid valve is opened and closed by moving a steel element called a plunger under the influence of solenoid electromagnetic forces and is used to control the flow of fluid in pipelines (open-close control).

  • The impact of water hammer is reduced, the valve closing time is reduced.
  • There are no leaks thanks to the slide mechanism made of synthetic rubber.
  • It is used for a wide range of pressures 0-1.0 MPa (0.1-1.0 MPa if the coil is turned to the side).
  • Mounting in horizontal and vertical positions (within 90 ° of the coil position vertically upwards).

Models DP-200, DP-200-N

Nom. the size d L H H 1 The weight
10A Rc 3/8 70 114 14.5 1.1
15A Rc 1/2 1.1
20A Rc 3/4 80 121 17.5 1,3
25A Rc 1 95 128 21.0 1.7
32A Rc 1-1 / 4 110 150 26.0 2.5
40A Rc 1-1 / 2 120 157 29.5 3.1
50A Rc 2 140 172 36.5 5.0

Models DP-200F, DP-200F-N

Nom. the size d L H H 1 The weight
15A 15 120 147 47.5 2.7
20A twenty 130 153 50.0 3.3
25A 25 145 169 62.5 4.8
32A 32 160 192 67.5 6.6
40A 40 170 198 70.0 7.3
50A 50 195 213 77.5 10.0

схемы Yoshitake DP-200, 200-N DP-200F, 200F-N

Nominal sizing diagram (for air)

диаграмма подбора номинального размера Yoshitake DP-200, 200-N DP-200F, 200F-N

How to use a chart

When selecting the nominal size of the solenoid valve at inlet pressure (P1), outlet pressure (P2) and air flow (Q) (20 ° C) 0.5 MPa, 0.3 MPa and 600 m3 / h (standard conditions), accordingly, first find the point of intersection (a) of the lines P1 = 0.5 MPa and P2 = 0.3 MPa. Draw a vertical line downward from this point (a) to the point of intersection (b) with the line Q = 600 m3 / h (standard conditions). Since this intersection point (b) lies between the nominal sizes 20A and 25A, choose the larger of the two, 25A.

Nominal sizing diagram (for water)

диаграмма подбора номинального размера Yoshitake DP-200, 200-N DP-200F, 200F-N для воды

How to use a chart

When selecting the nominal size of the solenoid valve at inlet pressure (P1), outlet pressure (P2) and flow rate (V) 0.6 MPa, 0.3 MPa and 200 l / min, respectively, first find the intersection point (a) of the lines differential pressure (∆P = 0.6 - 0.3 = 0.3 MPa) and V = 200 l / min. Since this intersection point (a) lies between dimensions 20A and 25A, choose the larger of the two, 25A.

Delivery

  • Pickup from a warehouse in Kiev - is free
  • New Mail - at the rates of the delivery service, at the rates of the delivery service, at the rates of the delivery service
  • SAT - at the rates of the delivery service
  • Deliveri - at the rates of the delivery service

Payment

  • Cashless payment with VAT
  • Online Privat24, Visa / MasterCard
Solenoid valve Yoshitake DP200 200N DP200F 200FN

All equipment catalog

Sorting
ApplyReset
Close
loading
loading