loading

Solenoid valve Yoshitake DP-100-D, 100F-D

Solenoid valve Yoshitake DP100D 100FDSolenoid valve Yoshitake DP100D 100FD
in stock
Price: specify

Quantity

Total

specify

  • Manufacturer: Yoshitake
  • Max. operating pressure: 1.0 MPa
  • Liquid temperature: 5-180 °C
  • Material: cast stainless steel, stainless steel, fluoroplastic
Quick order
Enter your phone number and
our manager will call you back
  • Specifications
  • Description
  • Dimensions and weight
  • Chart
  • Delivery and payment
Parameter name Meaning
Model
DC coil current DP-100-D DP-100F-D
Nominal size
10A-50A 15A-65A
Design
Plunger type, pilot
Application
Steam, air, cold and hot water, nitrogen, carbon dioxide (dry), argon, oil (up to 20 cSt)
Operating pressure
0-1.0 MPa (does not work during evacuation)
Min. differential pressure
0 MPa (minimum 0.03 MPa required in case of vertical mounting)
Permitted. valve seat leak
50 ml / min under standard conditions (at an air pressure of 0.6 MPa)
Temperature range
5-180 ° C (freezing not allowed)
Material
Frame Cast stainless steel (SCS14A)
Plunger Stainless steel (SCS14A)
Valve plug Fluoroplastic
Compound
Threaded JIS Rc Flanged JIS 10K FF












Stainless steel DC coil current
Norm. closed
With threaded connection DP-100-D
Flanged DP-100F-D

Coil Specifications

Rated voltage -12 V -24 V -48 V
Nominal size 10-25A 32-65A 10-25A 32-65A 10-25A 32-65A
Rated current 2.73 A 2.35 A 1.34 A 1.14 A 0.67 A 0.59 A
Permissible fluctuations Rated voltage: -5% to + 10%
Insulation class Insulation class H
Protective structure Dust-proof and splash-proof
Degree of protection IP64 (JIS C0920)
Insulation resistance Not less than 50 MOhm at 500 V
Withstand voltage 1500 V / min

* Available with terminal box.

The solenoid valve is opened and closed by moving a steel element called a plunger under the influence of solenoid electromagnetic forces and is used to control the flow of fluid in pipelines (open-close control).

  • Plunger-type solenoid valve with DC power supply current.
  • Installation in horizontal and vertical positions.

Model DP-100-D

Nom. the size d L H 1 H The weight
10A Rc 3/8 70 14.5 143 2.2
15A Rc 1/2 70 14.5 143 2.2
20A Rc 3/4 80 17.5 147 2,3
25A Rc 1 95 21.0 151 2.7
32A Rc 1-1 / 4 110 26.0 194 4.3
40A Rc 1-1 / 2 120 29.5 200 5.2
50A Rc 2 140 36.5 209 6.8

Model DP-100F-D

Nom. the size d L H 1 H The weight
15A 15 120 47.5 177 3.5
20A twenty 130 50.0 180 4.0
25A 25 145 62.5 193 5.3
32A 32 160 67.5 235 8.1
40A 40 170 70.0 241 9.2
50A 50 195 77.5 250 11.7
65A 50 198 87.5 260 13.5

схемы Yoshitake DP-100-D, 100F-D

Nominal sizing diagram (for steam)

Диаграмма подбора номинального размера (для пара)

How to use a chart

When selecting the nominal size of the solenoid valve with inlet pressure (P1), outlet pressure (P2) and steam flow (W) (saturated steam) 0.7 MPa, 0.5 MPa and 400 kg / h, respectively, first find the point intersection (a) of lines P1 = 0.7 MPa and P2 = 0.5 MPa. From this point, draw a line down to the intersection with the line corresponding to the flow rate W = 400 kg / h - the point of intersection (b). Since this intersection point (b) lies between nominal sizes 15A and 20A, choose the larger of the two, 20A.

Nominal sizing diagram (for water)

Диаграмма подбора номинального размера (для воды)

How to use a chart

When selecting the nominal size of the solenoid valve with inlet pressure (P1), outlet pressure (P2) and flow (V) 0.5 MPa, 0.35 MPa and 150 l / min, respectively, first find the intersection point (a) of the lines differential pressure (∆P = 0.5 - 0.35 = 0.15 MPa) and V = 150 l / min. Since this intersection point (a) lies between dimensions 20A and 25A, choose the larger of the two, 25A.

Nominal sizing diagram (for air)

Диаграмма подбора номинального размера (для воздуха)

How to use a chart

When selecting the nominal size of the solenoid valve at inlet pressure (P1), outlet pressure (P2) and air flow (Q) (20 ° C) 0.4 MPa, 0.3 MPa and 300 m3 / h (standard conditions), accordingly, first find the point of intersection (a) of the lines P1 = 0.4 MPa and P2 = 0.3 MPa. Draw a vertical line downward from this point (a) to the point of intersection (b) with the line Q = 300 m3 / h (standard conditions). Since this intersection point (b) lies between nominal sizes 15A and 20A, choose the larger of the two, 20A.

Delivery

  • Pickup from a warehouse in Kiev - is free
  • New Mail - at the rates of the delivery service, at the rates of the delivery service, at the rates of the delivery service
  • SAT - at the rates of the delivery service
  • Deliveri - at the rates of the delivery service

Payment

  • Cashless payment with VAT
  • Online Privat24, Visa / MasterCard
Solenoid valve Yoshitake DP100D 100FD

All equipment catalog

Sorting
ApplyReset
Close
loading
loading