Model | GP-27VR | |
Nominal size | 20-100A | |
Application | Cold and hot water | |
Inlet pressure | 1.0 MPa or less | |
Reduced pressure | (A) 0.05-0.35 MPa (B) 0.3-0.7 MPa | |
Min. differential pressure | 0.05 MPa | |
Maximum pressure reduction ratio | 10: 1 | |
Maximum temperature | 90 ° C | |
Material | Frame | Cast bronze (NPb finish) |
Valve seat | Cast bronze (NPb finish) | |
Valve plug | Fluoroelastomer | |
Membrane | Ethylene Propylene Rubber | |
Compound | Flange connection JIS 10K FF | |
Installation position | Horizontal or vertical installation is possible (for 100A installation only on horizontal piping in the upper position. See * 1 below). |
Pressure gauge connection with JIS Rc 1/4 thread.
Supplied with a pressure gauge.
The pressure reduction function is set when shipped from the factory.
Mounting position 100A
Function
The switching of the three functions (pressure reduction function, bypass function and shut-off function) is carried out using the operating rods on the inlet and outlet side and the direction of the arrow to a specific point on the plate. Refer to the illustration to the right for the correct arrow setting and fluid flow for each function. (In the picture, the arrow is in the position for the pressure reduction function)
Pressure reduction function
Bypass function
Shut-off function
- The combination of pressure relief, bypass and shut-off function saves cost and space.
- Provides a wide range of pressure regulation in the water supply system.
- Parts of the flow path are made of corrosion-resistant material, which eliminates the presence of rusty water.
- The pressure balanced design of the valve allows the reduced pressure to be kept constant without being influenced by the inlet pressure.
- By opening only the top of the valve, maintenance and inspection is easy.
Nominal size | L | H 1 | H 2 | d | The weight |
20A | 200 | 61 | 137 | eighteen | 6 |
25A | 200 | 61 | 137 | eighteen | 7 |
32A | 245 | 72 | 177 | eighteen | eleven |
40A | 245 | 72 | 177 | 28 | 12 |
50A | 260 | 92 | 186 | 28 | 16 |
65A | 328 | 99 | 257 | 45 | thirty |
80A | 402 | 112 | 274 | 56 | 38 |
100A | 470 | 134 | 328 | 72 | 58 |
Selection of nominal size
[The differential pressure before and after the valve is not less than 0.15 MPa.]
Nominal size | 20A | 25A | 32A | 40A | 50A | 65A | 80A | 100A |
---|---|---|---|---|---|---|---|---|
Consumption, l / min | 40 | 60 | 100 | 150 | 250 | 300 | 450 | 700 |
* If the differential pressure upstream and downstream of the valve is less than 0.15MPa, select the correct nominal size using the diagram below.
Flow characteristics graph
Nominal size: 20A-50A
Flow characteristics graph
Nominal size: 65A-100A
Flow characteristics graph
* Pressure offset
- | Decrease range pressure | Pressure offset |
A | 0.05-0.35 MPa | No more than 0.10 MPa |
B | 0.30-0.70 MPa | No more than 0.15 MPa |
Noise performance graph
Nominal size 20A-25A
Noise performance graph
Nominal size 32A-50A
Noise performance graph
Nominal size 65A-100A
Pressure curve
This graph shows the change in reduced pressure when the pressure of 0.6 MPa at the valve inlet begins to fluctuate between 0.15 MPa and 1.0 MPa, while the reduced pressure is set at 0.1 MPa.
Delivery
- Pickup from a warehouse in Kiev - is free
- New Mail - at the rates of the delivery service, at the rates of the delivery service, at the rates of the delivery service
- SAT - at the rates of the delivery service
- Deliveri - at the rates of the delivery service
Payment
- Cashless payment with VAT
- Online Privat24, Visa / MasterCard