Apply | Steam | |
Inlet pressure | 0.1-1.0 MPa | |
Reduced pressure | 0.02-0.15 MPa 0.1-0.85 MPa | |
Max temperature | 183 °C | |
Solenoid valve actuation | Normally closed | |
Rated voltage | Available options: 100 VAC current, 50/60 Hz; 200 V a.c. current, 50/60 Hz | |
Connection | Threaded JIS Rc Flanged JIS 10K FF | |
Material | Main valve body | Ductile iron |
Head. valve, valve seat | Stainless steel | |
Membrane | Stainless steel | |
Nominal size | Threaded connection: 15A-50A Flanged connection: 15A-100A |
Contact us for other specifications.
High pressure and low pressure steam lines are used together to increase the capacity and efficiency of the system and save energy. In this case, at least two valves must be used. Air is blown in with low pressure steam and then rapidly raised to the required temperature with high pressure steam; normal operation starts with low pressure steam. These actions can be performed by one valve of the СР-2003 series.
Control example
Solenoid valve ON | Р1=1.0 MPa Р2=0.5 MPa |
Solenoid valve OFF | Р1=1.0 MPa Р2=0.2 MPa |
On-off pressure switch
Diaphragm valve with "pilot" high precision low pressure control. This option is optimal if pressure surges significantly affect quality.
Delivery
- Pickup from a warehouse in Kiev - is free
- New Mail - at the rates of the delivery service, at the rates of the delivery service, at the rates of the delivery service
- SAT - at the rates of the delivery service
- Deliveri - at the rates of the delivery service
Payment
- Cashless payment with VAT
- Online Privat24, Visa / MasterCard