  • Manufacturer: Tesy (Bulgaria)
  • Volume: 1500(l)
  • Container material: enamel coated carbon steel
  • Maximum working temperature: 110(° C)
  • Designation of tanks: alternative energy systems, heating systems, hot water systems
  • Heat exchanger: lower
  • Heat transfer surface area: 3.3(m²)
  • Insulation: Yes
Quick order
Enter your phone number and
our manager will call you back
  • Specification
  • Dimensions and weight
  • Equipment selection
  • Options
  • Delivery and payment

Maximum operating temperature of the heat exchanger - 110 ° С

Model
Volume,
The weight,
Heat exchange area,
Heat exchanger volume,
Heat loss ΔT 45K,
l
Kg
m 2
l
kW / 24h
V 12S 1500 120 F45 P5
1500
371
3.47
31.4
6.5
Dimensions [± 5mm], mm V 12S 1500 120 F45 P5
a 2216
b 1726
with 1293
d 860
e 427
g 1087
h 647
D 40
øC 1200
øD 1000
R1 2270

TESY V 12S 1500


L1; 2; 3; 4 - branch pipe for inlet / outlet of liquid - 1; 2; 3; 4 - G½ "
TS1; 2; 3; 4 - thermal sensor 1; 2; 3; 4 - G½ "
TSS1 - heat flux density meter - G½ "
IS1 - incoming heat carrier flow - G1½ "
OS1 - outgoing heating medium flow - G1½ "
AV - ventilation opening - G1½ "
D - G¾ "
V 12S 1500 120 F45 P5, V 15S 2000 130 F46 P5
L1; 2; 3; 4 - branch pipe for inlet / outlet of liquid - 1; 2; 3; 4 - G2 "
TS1; 2; 3; 4 - thermal sensor 1; 2; 3; 4 - G½ "
TSS1 - heat flux density meter - G½ "
IS1 - incoming heat carrier flow - G1½ "
OS1 - outgoing heating medium flow - G1½ "
AV - ventilation opening - G2 "
D - G¾ "

To select the required storage volume, it is possible to combine several tanks into a cascade.

The storage tank is selected for the previously selected heat source and is calculated in such a way that it can accumulate all the heat generated by this source, or for the consumer of which it should be provided with heat generated before the time of heat consumption by a low-power source.

The priority in the selection of the capacity will be the source if its power or the time of heat input is limited.

The priority in the selection of the capacity will be the consumer, if it is required to cover a given heat load in a certain time.
The additional volume of water formed during heating to the maximum temperature is ~ 3.5% of the nominal volume of the container.

  • vertical / horizontal placement;
  • security group;
  • level / temperature / pressure sensors;
  • thermoelectric heater;
  • heat exchanger;
  • insulation in the cold;
  • cathodic protection;
  • service;
  • inspection hatch; leather / fabric cover;
  • development of individual equipment *

Delivery

  • Pickup from a warehouse in Kiev - is free
  • New Mail - at the rates of the delivery service, at the rates of the delivery service, at the rates of the delivery service
  • SAT - at the rates of the delivery service
  • Deliveri - at the rates of the delivery service

Payment

  • Cashless payment with VAT
  • Online Privat24, Visa / MasterCard
Indirect heating boiler 1500 liters TESY V 12S 1500

All equipment catalog

Sorting
ApplyReset
Close
loading
loading