Model |
|
| 200 | 300 | 400 | 500 | 600 |
| Volume | l | 205 | 330 | 410 | 495 | 585 |
d | Diameter without insulation | mm | 400 | 500 | 550 | 600 | 650 |
D | Insulated diameter | mm | 500 | 600 | 650 | 700 | 750 |
HT | Height | mm | 1855 | 1905 | 1925 | 1950 | 1975 |
FL | Inspection hatch diameter | mm | 120 × 180 |
SS1 | Heating area of the bottom spiral heat exchanger | m 2 | 1.50 | 1.80 | 1.90 | 2.20 | 2.50 |
| Lower spiral heat exchanger volume | l | 7.1 | 8.5 | 8.9 | 10.3 | 11.8 |
SS2 | Heating area of the upper spiral heat exchanger | m 2 | 0.50 | 1.10 | 1.00 | 1.30 | 1.90 |
| Upper spiral heat exchanger volume | l | 2.4 | 5.2 | 4.7 | 6.1 | 8.9 |
TO | Maximum tilt height | mm | 1921 | 1997 | 2032 | 2072 | 2113 |
| Tank weight | Kg | 80 | 110 | 135 | 155 | 210 |
| Connections |
|
|
|
|
E | Cold water outlet |
| G¾ " | G¾ " | G¾ " | G¾ " | G¾ " |
U | Hot water outlet |
| G¾ " | G¾ " | G¾ " | G¾ " | G¾ " |
RC | Recirculation |
| G¾ " | G¾ " | G¾ " | G¾ " | G¾ " |
RE | Connection for heating element |
| G1 "½ | G1 "½ | G1 "½ | G1 "½ | G1 "½ |
A | Connection for magnesium anode |
| G1 "¼ | G1 "¼ | G1 "¼ | G1 "¼ | G1 "¼ |
Sf | Air outlet |
| G1½ " | G1½ " | G1½ " | G1½ " | G1½ " |
So1-So2 | Connecting sensors |
| G½ " | G½ " | G½ " | G½ " | G½ " |
T | Thermometer / Thermostat |
| G½ " | G½ " | G½ " | G½ " | G½ " |
S1-S3 | Heating circuit inlet / outlet (bottom heat exchanger) |
| G1 " | G1 " | G1 " | G1 " | G1 " |
S2-S4 | Heating circuit inlet / outlet (upper heat exchanger) |
| G1 " | G1 " | G1 " | G1 " | G1 " |
| Technical details |
|
|
|
|
PE | Maximum working pressure of the tank | bar | ten | ten | ten | ten | ten |
PC | Tank test pressure | bar | 15 | 15 | 15 | 15 | 15 |
| Maximum working pressure of the heat exchanger | bar | 12 | 12 | 12 | 12 | 12 |
| Heat exchanger test pressure | bar | 16 | 16 | 16 | 16 | 16 |
TE | Max. working temperature | ° C | 100 | 100 | 100 | 100 | 100 |