| Parameter name | Meaning | |||
| Model | OB-1 | OB-1G | ||
| Application | Heat | Steam, hot water | ||
| Heat. Wednesday | Cold and hot water, oil, other non-hazardous liquids | |||
| Max. pressure | Frame | 0.7 MPa | ||
| Thermal balloon | 1.0 MPa | |||
| Max. temperature | 180 ° C | |||
| Setting range temp. | For liquid | 40-120 ° C | 15-100 ° C | |
| For air | 40-120 ° C | 15-100 ° C | ||
| Pace. surrounded Wednesday | Set temperature -10 ° C or less | Set temperature +30 ° C or less | ||
| Material | Frame | Cast bronze | ||
| Valve | Phosphor bronze | |||
| Valve stem | Stainless steel | |||
| Bellows | Phosphor bronze | |||
| Thermal balloon | Stainless steel | |||
| Std. capillary length | 2 m | |||
| Compound | Threaded connection (split coupling) JIS Rc | |||
• In case the ambient temperature is above the set temperature or below 40 ° C, use OB-1G (with external pressure bellows). • Available with capillary tube up to 5 m long. • Available with sleeve (made of SUS304 or PTFE cap) for liquid.
Temperature setting range
OB-1
| Temperature setting range (° С) | Withstanding temperature (° C) | |
| For liquid | For air | |
| 40-60 | 40-60 | 70 |
| 50-70 | 50-70 | 80 |
| 60-80 | 60-80 | 90 |
| 80-100 | 80-100 | 110 |
| 100-120 | 100-120 | 130 |
The term withstand temperature refers to the maximum temperature at which the bellows can withstand internal pressure.
Variants with a temperature control range of 30 ° C are available (only OB-1).
OB-1G
| Temperature setting range (° С) | Withstanding temperature (° C) | |
| For liquid | For air | |
| 15-35 | 15-35 | 50 |
| 20-40 | 20-40 | 50 |
| 35-55 | 35-55 | 70 |
| 40-60 | 40-60 | 90 |
| 50-70 | 50-70 | 100 |
| 60-80 | 60-80 | 110 |
| 70-90 | 70-90 | 120 |
| 80-100 | 80-100 | 130 |
The term withstand temperature refers to the maximum temperature at which the bellows can withstand internal pressure.
- Easy installation thanks to the split threaded sleeve.
- Temperature adjustment is carried out using a knob without the need for additional tools.
- The double valve design allows higher flow rates than a single valve.
- Exceptional precision thanks to a special stem packing that influences the opening / closing of the valve.
- The OB-1G model provides excellent thermal stability thanks to the external pressure bellows.
| Nom. the size | d | L | H 1 | H | The weight |
| 15A | Rc 1/2 | 148 | 55 | 510 | eleven |
| 20A | Rc 3/4 | 148 | 55 | 510 | eleven |
| 25A | Rc 1 | 160 | 60 | 520 | 12 |
| 32A | Rc 1-1 / 4 | 195 | 60 | 520 | 12 |
| 40A | Rc 1-1 / 2 | 210 | 65 | 530 | 13 |


How to use a chart
When selecting the nominal size of the temperature controller at inlet pressure (P1), outlet pressure (P2) and steam flow rates of 0.3 MPa, 0.25 MPa and 60 kg / h, respectively, first find the point of intersection (a) of the pressure lines on inlet 0.3 MPa and outlet pressure 0.25 MPa. From this point (a) draw a line down to the intersection with the line corresponding to the flow rate of 60 kg / h - the point of intersection (b). Since this intersection point (b) lies between the nominal sizes 15A or 20A and 25A, select the larger one, 25A.
* The flow chart is for reference.
Leakage through valve seat Unit: steam (kg / h), water (l / h)
| 15A | 20A | 25A | 32A | 40A | 50A | 65A | 80A | 100A | 125A | 150A |
| 1.5 | 1.5 | 1.8 | 2.4 | 3.0 | 3.6 | 4.8 | 6.0 | 7.2 | 9.0 | 10.8 |
* The values shown in the table above are the maximum leakage values at 0.5 MPa or maximum pressure and set temperature + 5 ° C (-5 ° C in case of cooling).
Delivery
- Pickup from a warehouse in Kiev - is free
- New Mail - at the rates of the delivery service, at the rates of the delivery service, at the rates of the delivery service
- SAT - at the rates of the delivery service
- Deliveri - at the rates of the delivery service
Payment
- Cashless payment with VAT
- Online Privat24, Visa / MasterCard
