| Model | GD-200C | |
| Application | Cold and hot water, oil (kerosene, heavy oil products A and B), air, other non-hazardous liquids | |
| Inlet pressure | 1.0 MPa or less | |
| Low pressure | 15A-80A (A) 0.05-0.25 MPa (B) 0.26-0.7 MPa 100A-150A (A) 0.05-0.25 MPa (B) 0.26-0.5 MPa | |
| Min. differential pressure | 0.05 MPa | |
| Max. coeff. pressure reduction | 10: 1 | |
| Minimum adjustable flow | Water: 5 l / min Air: 10 m³ / hour (standard conditions) | |
| Working temperature | 5-60 ° C | |
| Fluid viscosity | No more than 600 cSt | |
| Material | Frame | Malleable cast iron |
| Valve seat | Stainless steel | |
| Valve plug | NBR | |
| Membrane | NBR | |
| Compound | Flange connection JIS 10K FF | |
| Internal processing case surface | Nylon 11 (inner and outer shell) | |
- Available with FPM components (except GD-200H (C) sizes 65A to 150A).
- Available with pressure gauge.
- GD-200HS available for rinse water.
- The pressure balanced design of the valve allows the reduced pressure to be kept constant without being influenced by the inlet pressure.
- High wear resistance and durability of the valve seat made of stainless steel.
- The valve top is easily removable for inspection and maintenance.
- A rubber stopper prevents leakage when the valve is closed.
- The GD-200C is highly corrosion resistant due to the nylon coated inside and outside of the case.
- Installation in horizontal or vertical pipelines is possible. (For sizes over 100A, installation is carried out on a horizontal pipeline in the upper position).
GD-200C
| Nominal size | L | H | H 1 | The weight |
| 15A | 145 | 296 | 557 | 8.3 |
| 20A | 150 | 296 | 57 | 8.3 |
| 25A | 150 | 318 | 67 | 10.1 |
| 32A | 195 | 398 | 76 | 17.4 |
| 40A | 195 | 398 | 76 | 17.4 |
| 50A | 195 | 412 | 81 | 19.3 |
| 65A | 270 | 573 | 113 | 40.1 |
| 80A | 270 | 598 | 128 | 43.8 |
| 100A | 308 | 666 | 146 | 70.1 |
| 125A | 380 | 875 | 182 | 144.1 |
| 150A | 400 | 930 | 207 | 173.1 |

Flow characteristics graph

* Minimum adjustable flow rate for aqueous medium: 5 l / min for air: 10 m3 / h, (standard conditions)
Pressure curve

This graph shows the dependence of the reduced pressure when the pressure at the valve inlet changes from 0.15 MPa to 1 MPa at a set reduced pressure of 0.10 MPa.
* Back pressure
| Nominal size | Pressure range | Pressure offset |
| 15A-50A | (A), (B) | Range of values 0.05-0.7 MPa within 0.05 MPa |
| (WITH) | Range of values 0.5-1.0 MPa within 0.11 MPa | |
| 65A, 80A | (A), (B) | Range of values 0.05-0.7 MPa within 0.05 MPa |
| (WITH) | Range of values 0.5-0.9 MPa within 0.11 MPa | |
| 100A | (A), (B) | Range of values 0.05-0.5 MPa within 0.05 MPa |
| (WITH) | Range of values 0.5-0.75 MPa within 0.11 MPa | |
| 125A-150A | (A) | Range of values 0.05-0.25 MPa within 0.05 MPa |
| (V) | Range of values 0.26-0.5 MPa within 0.07 MPa | |
| (WITH) | Range of values 0.5-0.75 MPa within 0.11 MPa |
Nominal sizing diagram (for water)

Nominal sizing diagram (for air)

The safety factor should be taken equal to 80-90%.
Delivery
- Pickup from a warehouse in Kiev - is free
- New Mail - at the rates of the delivery service, at the rates of the delivery service, at the rates of the delivery service
- SAT - at the rates of the delivery service
- Deliveri - at the rates of the delivery service
Payment
- Cashless payment with VAT
- Online Privat24, Visa / MasterCard
